| Sign In | Join Free | My himfr.com |
|
| Ask Lasest Price | |
| Model Number : | PTN 970C |
| Brand Name : | HW |
| Supply Ability : | 1000 Carton/Cartons per Day |
| Price : | $5,200.00/pieces >=2 pieces |

Height [mm] | 88.9 mm | ||||
Depth [mm] | 220 mm | ||||
Wide [mm] | 442 mm | ||||
Chassis height [U] | 2U | ||||
Weight without packaging (full configuration) | 10.1 kg (22.27 lb) | ||||
Weight without packaging | 4.2 kg (9.26 lb) | ||||
Typical power consumption (with configuration) [W] | 190G Typical configuration I:
2*50GE(1*50GE,2pcs)+2*10GE(2*10GE,1pcs)+8*GE(o)(10*GE,1pcs)+16*E1(16*E1,1pcs)
Typical power consumption: 220.22 W 190G Typical configuration II: 2*50GE(1*50GE,2pcs)+4*10GE(4*10GE,1pcs)+8*GE(o)(10*GE,1pcs)+16*E1(16*E1,1pcs) Typical power consumption: 224.63 W 190G Typical configuration III: 2*50GE(1*50GE,2pcs)+2*25GE(2*25GE,1pcs)+2*10GE(2*10GE,1pcs)+16*GE(o)(10*GE,2pcs) Typical power consumption: 247.56 W | ||||
Heat dissipation mode | Air cooling | ||||
Typical heat dissipation (with configuration) [BTU/h] | 190G Typical configuration I:
2*50GE(1*50GE,2pcs)+2*10GE(2*10GE,1pcs)+8*GE(o)(10*GE,1pcs)+16*E1(16*E1,1pcs)
Heat dissipation:701.68BTU/hour 190G Typical configuration II: 2*50GE(1*50GE,2pcs)+4*10GE(4*10GE,1pcs)+8*GE(o)(10*GE,1pcs)+16*E1(16*E1,1pcs) Heat dissipation:716.00BTU/hour 190G Typical configuration III: 2*50GE(1*50GE,2pcs)+2*25GE(2*25GE,1pcs)+2*10GE(2*10GE,1pcs)+16*GE(o)(10*GE,2pcs) Heat dissipation:790.39BTU/hour | ||||
Power supply mode | DC | ||||
Input voltage range [V] | –40 V to –72 V | ||||
Rated input voltage [V] | –48 V/–60 V | ||||
Maximum input current [A] | 30 A | ||||
Rated output power [W] | 1200 W | ||||
Number of service board slots | 6 | ||||
Number of slots | 11 | ||||
Redundant fans | The device can run at the temperature of 40˚C in the short term
after a single fan fails. | ||||
Redundant CXPs | 1+1 | ||||
Redundant power supply | 1+1 | ||||
Noise at normal temperature (acoustic power) | 55dBA@normal temperature | ||||
Airflow direction | From left to right | ||||
Maximum input cable size | 4 mm² (0 to 10m) | ||||
Front-end circuit breaker/fuse | Less than 190G: ≥ 16 A Note: Based on long-term evolution
requirements and site conditions, the recommended current is
greater than or equal to 32 A. | ||||
Restriction on the operating temperature variation rate | 30°C/hour (86°F/hour) | ||||
Long-term operating temperature | -20°C to 60°C(-4.0°F to 140.0°F) | ||||
Storage temperature | -40°C to 70°C(-104.0°F to 158.0°F) | ||||
Long-term operating relative humidity [RH] | 10% RH to 90% RH, non-condensing | ||||
Storage relative humidity [RH] | 10% RH to 100% RH, non-condensing | ||||
Long-term operating altitude | ≤ 4000 m. When the altitude is between 1800 m and 4000 m, the
device operating temperature decreases by 1 °C every time the altitude increases by 220 m. | ||||
Storage altitude | < 5000 m(< 16404.2 ft.) | ||||
MTBF [year] | 40 | ||||
MTTR [h] | 2 | ||||
Availability | 0.99999 | ||||
Maximum number of 25GE ports | 4 | ||||
Maximum number of GE ports | 60 | ||||
Maximum number of electrical ports | 48 | ||||
Maximum number of 100GE ports | 0 | ||||
Maximum number of 40GE ports | 0 | ||||
Maximum number of 10GE ports | 20 | ||||
Maximum number of FE ports | 60 | ||||
Maximum number of 50GE ports | 2 | ||||















|