| Sign In | Join Free | My himfr.com |
|
| Ask Lasest Price | |
| Model Number : | PTN 970 |
| Brand Name : | HW |
| Supply Ability : | 1000 Carton/Cartons per Day |
| Price : | $1,200.00/pieces >=2 pieces |

Height [mm] | 88.9 mm | ||||
Depth [mm] | 220 mm | ||||
Wide [mm] | 442 mm | ||||
Chassis height [U] | 2U | ||||
Weight without packaging (full configuration) | 9.4 kg (20.73 lb) | ||||
Typical power consumption (with configuration) [W] | Typical power consumption of 120 G system:
2*10GE+8*GE(o)+8*GE(e)+16E1 Typical Power consumption: 172 W
Typical power consumption of 190 G system I: 2*50GE+2*25G+2*10G+16*GE(o) Typical Power consumption: 237 W Typical power consumption of 190 G system II: 2*50GE+4*10G+8*GE(o)+16E1 Typical Power consumption: 211 W Typical power consumption of 190 G system III: 2*50GE+2*10G+8*GE(o)+16E1 Typical Power consumption: 210 W | ||||
Heat dissipation mode | Air cooling | ||||
Typical heat dissipation (with configuration) [BTU/h] | Typical configuration of the 120 G system: 2*10 GE + 8*GE (o) +
8*GE (e) + 16E1 Heat dissipation 558 BTU/hour Typical configuration of the 190 G system: 2*50 GE+2*25G+2*10 G+16*GE (o) Heat dissipation 768.9 BTU/hour Typical configuration of the 190 G system: 2*50 GE+4*10 G+8*GE (o)+16E1 Heat dissipation 684.6 BTU/hour Typical configuration of the 190 G system: 2*50 GE+2*10 G+8*GE (o)+16E1 Heat dissipation 681.3 BTU/hour | ||||
Power supply mode | DC | ||||
Input voltage range [V] | -38.4 V to -72 V | ||||
Rated input voltage [V] | –48 V/–60 V | ||||
Maximum input current [A] | 10 A | ||||
Number of slots | 11 | ||||
Redundant fans | The device can run at the temperature of 40˚C in the short term
after a single fan fails. | ||||
Redundant CXPs | 1+1 | ||||
Redundant power supply | 1+1 | ||||
Noise at normal temperature (acoustic power) | 55dB(A)@normal temperature | ||||
Maximum input cable size | 4 mm² (10 meters) | ||||
Front-end circuit breaker/fuse | ≥16 A | ||||
Restriction on the operating temperature variation rate | 30°C/hour (86°F/hour) | ||||
Long-term operating temperature | -20°C to 60°C(-4.0°F to 140.0°F) | ||||
Storage temperature | -40°C to 70°C(-104.0°F to 158.0°F) | ||||
Long-term operating relative humidity [RH] | 10% RH to 90% RH, non-condensing | ||||
Storage relative humidity [RH] | 10% RH to 100% RH, non-condensing | ||||
Long-term operating altitude | ≤ 4000 m. When the altitude is between 1800 m and 4000 m, the
device operating temperature decreases by 1 °C every time the altitude increases by 220 m. | ||||
Storage altitude | < 5000 m(< 16404.2 ft.) | ||||
MTBF [year] | 40 | ||||
MTTR [h] | 2 | ||||
Availability | 0.99999 | ||||
MTTR [h] | 2 | ||||
Availability | 0.99999 | ||||















|