    Model Number : NetEngine 8000 X4
    Brand Name : HW
    Supply Ability : 1000 Carton/Cartons per Day
    Price : $7,100.00/pieces >=2 pieces
    • Product Details
    • Company Profile

    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps

    PRODUCT DESCRIPTION
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    TECHNICAL SPECIFICATION
    Item
    Specification
    Cabinet installation standards
    The chassis can be installed in a 19-inch standard cabinet with a depth not less than 1000 mm. A 1200 mm deep cabinet is
    recommended.
    By default, Hu awei A612 cabinet (2200 mm high x 1200 mm deep) is used. The cabinet BOM number is 02116153 (CR8B22A612C0).
    Hu awei A610 cabinet (2200 mm high x 1000 mm deep) with a convex front door can be used. The BOM number of the cabinet is 02116078
    (CR8B0A610E60).
    A Hu awei cabinet is recommended. If a third-party cabinet is used, the front door of the cabinet must be equipped with an air
    filter, but the rear door of the cabinet cannot be equipped with any air filter. (If an air filter is installed on the rear door,
    uninstall it.)
    Dimensions without packaging (H x W x D) [mm(in.)]
    438 mm x 442 mm x 874 mm (17.24 in. x 17.40 in. x 34.40 in.) (dimensions of the chassis body)
    438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.) (including the chassis front and rear decorating parts and cable
    tray)
    Dimensions with packaging (H x W x D) [mm(in.)]
    730 mm x 770 mm x 1150 mm(28.74 in. x 30.31 in. x 45.28 in.)
    Chassis height [U]
    9.8 U
    Weight without packaging [kg(lb)]
    72 kg (158.7 lb)
    Weight with packaging [kg(lb)]
    138 kg (304.2 lb)
    Weight without packaging (full configuration) [kg(lb)]
    4T bundle: 192.7 kg (424.8 lb)
    14.4T bundle: 210.1 kg (463.2 lb)
    Typical power consumption (with configuration) [W]
    5240 W (estimated value when LPUI-4T boards are fully configured)
    8860 W (LPUI-14.4T boards are fully configured)
    Typical heat dissipation (with configuration) [BTU/hour]
    17324 BTU/hour
    MTBF [year]
    18.71 year
    MTTR [hour]
    0.5 hour
    Availability
    0.99999
    Power supply mode
    AC/HVDC built-in
    Maximum number of power chassis inputs
    (12 channels/PEM)*1 PEM=(2 channel/PM)*6 PM*1 PEM=12 channels
    Rated input voltage [V]
    AC: 200 V to 240 V
    HVDC: 240 V/380 V
    Input voltage range [V]
    AC: 176 V to 290 V
    HVDC: 188 V to 400V
    Maximum input current [A]
    AC: 16 A per module
    HVDC: 14 A per module
    Maximum input cable size [mm²]
    2.5 mm²
    Front-end circuit breaker/fuse [A]
    AC:
    UPS power distribution: two 16 A inputs per module, six PMs, twelve 16 A inputs in total
    Mains power distribution: two 20 A inputs per module, six PMs, twelve 20 A inputs in total
    HVDC:
    Two 16 A inputs per module, six PMs, twelve 16 A inputs in total
    Heat dissipation mode
    air cooling
    Airflow direction
    Front-to-back airflow
    Number of slots
    14
    Number of service board slots
    4
    Switching capacity
    41.89 Tbit/s (4T bundle)
    173.15 Tbit/s (14.4T bundle)
    Redundant MPUs
    1:01
    Redundant Switch fabrics
    7+1
    Redundant power supply
    4+1
    Redundant fans
    3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
    Long-term operating temperature [°C(°F)]
    0 °C to 40 °C (32°F to 104°F)
    Short-term operating temperature [°C(°F)]
    -5 °C to 50 °C (23°F to 122°F)
    Restriction on the operating temperature variation rate [°C(°F)]
    ≤ 30°C/hour (54°F/hour)
    Storage temperature [°C(°F)]
    -40 °C to 70 °C(–40°F to 158°F)
    Long-term operating relative humidity [RH]
    5% to 85%, non-condensing
    Short-term operating relative humidity [RH]
    5% to 95% RH, non-condensing
    Storage relative humidity [RH]
    5% to 95% RH, non-condensing
    Long-term operating altitude [m(ft.)]
    ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
    of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].)
    Storage altitude [m(ft.)]
    < 5000 m (16404.199 ft.)
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    COMPANY PROFILE
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    Why Choose Us
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    Exhibition
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    Certifications
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    Client Evaluation
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    Packing & Delivery
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    1. Who are we?
    We are based in Beijing, China, start from 2023,sell to Domestic Market(60.00%),North America(20.00%),South America(10.00%),Western Europe(10.00%). There are total about 11-50 people in our office.

    2. How can we guarantee quality?
    Always a pre-production sample before mass production;
    Always final Inspection before shipment;

    3. What can you buy from us?
    Microwave Equipment, Data Communication Equipment, Transmission Equipment, Storage Device, Server

    4. Why should you buy from us not from other suppliers?
    Microwave equipment:RTN910A/RTN905F/RTN950/RTN950A/RTN980/RTN980L/RTN320F/RTN380AX; Wavelength division equipment:OSN9800/OSN9600/ONS8800; OLT:MA5800X2/X7; Switch:S9310X/CE6881-48S6CQ-B/CE8851-32CQ8DQ-P/CE6863E-48S6CQ. OceanStor Dorado 6000 V6/2288H V6/5288V6

    5. What services can we provide?
    Accepted Delivery Terms: FOB,EXW;
    Accepted Payment Currency:USD,CNY;
    Accepted Payment Type: T/T;
    Language Spoken:English,Chinese
    AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps
    Quality AC HVDC 02353CVY Chassis NetEngine 8000 X4 Router with High Throughput 1.44 Tbps for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Shandian Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)