Sign In | Join Free | My himfr.com
Home > Switch Router Firewall >

Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG

    Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
     
    Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
    • Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
    • Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
    • Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
    • Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
    • Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers
    • Buy cheap Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG from wholesalers

    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG

    Ask Lasest Price
    Model Number : CloudEngine 8850-64CQ-EI
    Brand Name : HUAWEI
    Price : $22,764.00/units 2-49 units
    • Product Details
    • Company Profile

    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG

    PRODUCT DESCRIPTION
    HUA WEI CloudEngine 8800 Series Data Center Switches CE8850-64CQ-EI

    CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,Without Fan and Power Module)

    CloudEngine 8800 series are Huawei's next-generation Ethernet switches designed for DCs, featuring high performance, high density, and low latency. Built on an advanced hardware structure, the switches support high-density 100GE/40GE/ 25GE/10GE ports. Running on Huawei's next-generation VRP8 operating system, they provide abundant DC features and high-performance stacking, and allow flexible selection of airflow directions. In addition, they can work with CloudEngine 16800/12800/6800/5800 series switches to build an elastic, virtual, and high-quality data center network (DCN), meeting network requirements of DCs in the cloud computing era
    CloudEngine 8800 series switches can function as core or aggregation switches on DCNs to help enterprises and carriers to build a DCN platform for the cloud computing era. They can also be used as aggregation or core switches on campus networks.
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Networking Application

    Typical Applications in DCs

    On a typical DCN, CloudEngine 16800, CloudEngine 12800, or CloudEngine 8800 series switches function as core switches, and CloudEngine 8800, CloudEngine 6800, or CloudEngine 5800 series switches function as ToR switches and interconnect with CloudEngine 16800, CloudEngine 12800, or CloudEngine 8800 series switches through 100GE/40GE/10GE ports. These switches use VXLAN and other fabric protocols to establish a non-blocking large Layer 2 network, which allows large-scale VM migration and flexible service deployment.

    Note: VXLAN can also be used on campus networks to support flexible service deployment in different service areas.
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Typical Applications on Campus Networks

    CloudEngine 8800 series switches can be used on campus networks. They provide industry's leading high-density full-line-speed 100GE/40GE ports and high-performance stacking to meet increasing network bandwidth requirements. CloudEngine 8800 series switches also stand out with abundant features and an innovative energy-saving mechanism. Thanks to their high cost-effectiveness, they are ideal for campus networks.

    On a typical campus network, multiple CloudEngine 16800, CloudEngine 12800, or CloudEngine 8800 series switches are virtualized into a logical core switch using CSS or iStack technology. Multiple CloudEngine 8800 or CloudEngine 6800 series switches at the aggregation layer form a logical switch using iStack technology. The resulting benefits include enhanced network reliability and simplified network management. At the access layer, CloudEngine 6800 or CloudEngine 5800 series switches are virtualized using CloudFabric technologies such as M-LAG to provide high-density line-speed ports.

    Note: CSS and M-LAG are also widely used in DCs to simplify network management.
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    TECHNICAL SPECIFICATION
    1.Hardware Specifications
    Item
    CloudEngine 8850E -32CQ-EI
    CloudEngine 8850-64CQ-EI
    Port description
    32 x 100GE QSFP28 + 1 x 10GE SFP+
    64 x 100GE QSFP28
    Switching capacity
    6.4 Tbps/102.4 Tbps
    12.8 Tbps/204.8 Tbps
    Packet forwarding rate
    2003 Mpps
    4482 Mpps
    Buffer
    32 MB
    42 MB
    Air duct type
    Standard front-to-back or back-to-front airflow
    Device virtualization
    Intelligent stack (iStack)
    M-LAG
    Data center interconnect (DCI)
    VXLAN mapping, enabling Layer 2 interconnection between DCs
    Network virtualization
    VXLAN routing and VXLAN bridging
    BGP-EVPN
    TRILL (supported only by the CloudEngine 8850-64CQ-EI)
    QinQ access VXLAN
    SDN
    iMaster NCE-Fabric
    Network convergence
    Fibre Channel over Ethernet (FCoE)
    Data Center Bridging Exchange Protocol (DCBX), Priority-based Flow Control (PFC), and expanded trunking system (ETS)
    Remote direct memory access (RDMA) and RoCE (RoCEv1 and RoCEv2)
    Programmability
    OPS programming
    Ansible-based automatic configuration and open-source module release
    Traffic analysis
    NetStream
    sFlow
    VLAN
    Access, trunk, and hybrid ports
    Default VLAN
    QinQ
    MUX VLAN
    GARP VLAN Registration Protocol (GVRP)
    MAC address entry
    Automatic MAC address learning and aging
    Static, dynamic, and blackhole MAC address entries
    Source MAC address filtering
    MAC address learning limiting by port and VLAN ID
    IP routing
    IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP
    IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+
    IPv6
    IPv6 VXLAN over IPv4
    VXLAN over IPv6 (supported only by the CE8850E-32CQ-EI)
    IPv6 neighbor discovery (ND)
    Path MTU Discovery (PMTU)
    TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6
    Multicast
    Multicast routing protocols, such as the Internet Group Multicast Protocol (IGMP) , Protocol Independent Multicast-Sparse Mode (PIM-SM), Protocol Independent Multicast-Dense Mode (PIM-DM), Multicast Source Discovery Protocol (MSDP), and Multicast BGP (MBGP)
    IGMP snooping
    IGMP proxy
    Fast leaving of multicast member interfaces
    Multicast traffic suppression
    Multicast VLAN
    Multicast VXLAN
    MPLS
    Basic MPLS
    Reliability
    Link Aggregation Control Protocol (LACP)
    STP, RSTP, VBST, and MSTP
    BPDU protection, root protection, and loop prevention
    Smart Link and multi-instance
    Device Link Detection Protocol (DLDP)
    Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms
    G.8032 Ethernet Ring Protection Switching (ERPS)
    VRRP, VRRP load sharing, and BFD for VRRP
    BFD for BGP, IS-IS, OSPF, and static routing
    BFD for VXLAN
    QoS
    Traffic classification based on Layer 2 protocol headers, Layer 3 protocol headers, and Layer 4 protocol priorities
    ACL, CAR, re-marking, and scheduling
    Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR
    Congestion avoidance mechanisms such as WRED and tail drop
    Traffic shaping
    Intelligent O&M
    Network-wide path detection
    1588v2 (supported only by the CloudEngine 8850-64CQ-EI)
    Telemetry
    INT (IOAM) and enhanced ERSPAN
    Intelligent traffic analysis
    RoCE traffic visualization: RoCE traffic KPI analysis
    Statistics collection on the buffer microburst status
    VXLAN OAM: VXLAN ping and VXLAN tracert
    Intelligent lossless network
    PFC deadlock prevention
    AI ECN: The switch intelligently adjusts the ECN thresholds of lossless queues based on the live-network traffic model.
    Fast CNP: The switch directly sends CNP packets to server NICs at the source end to shorten the CNP feedback path.
    DLB
    ECN overlay
    INC (supported only by the CE8850-64CQ-EI)
    Configuration and maintenance
    Terminal login through the console port, Telnet, and SSH
    Network management protocols, such as SNMPv1/v2/v3
    File upload and download through FTP and TFTP
    Boot Read-Only Memory (BootROM) upgrade and remote online upgrade
    802.3az Energy Efficient Ethernet (EEE)
    Hot patch
    User operation log
    Configuration rollback
    ZTP
    Security and management
    802.1X authentication
    Command line authority control based on user levels, preventing unauthorized users from using commands
    Defense against DoS, ARP, and ICMP attacks
    Port isolation, port security, and sticky MAC
    Binding of the IP address, MAC address, port ID, and VLAN ID
    Authentication methods, including AAA, RADIUS, and HWTACACS
    RMON
    Dimensions (H x W x D)
    442.0mm × 420.0mm × 43.6mm
    442.0mm×600.0mm×86.1mm
    Weight (full configuration)
    8.6 kg
    16.4 kg
    Environment requirements
    Operating temperature: 0°C to 40°C (0 m to 1800 m) Storage temperature: -40°C to +70°C
    Relative humidity: 5% RH to 95% RH (noncondensing)
    Operating voltage
    600 W AC&240 V DC power module:
    AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz DC: 190 V DC to 290 V DC
    1000 W DC power module: -38.4 V DC to -72 V DC 1200 W high-voltage DC power module: 190 V DC
    to 400 V DC
    1200 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz DC: 190 V DC to 290 V DC
    1200 W DC power module: -38.4 V DC to -72 V DC; +38.4 V DC to +72 V DC
    Typical power consumption
    203 W (100% traffic load, copper cables on half of the ports, normal temperature, dual AC power modules)
    244 W (100% traffic load, short-distance optical modules on half of the ports, normal temperature, dual AC power modules)
    376 W (100% traffic load, QSFP28 high-speed cables on 32 ports, normal temperature, dual AC power modules)
    455 W (100% traffic load, QSFP28 short-distance optical modules on 32 ports, normal temperature, dual AC power modules)
    Maximum power consumption
    339 W (100% traffic load, short-distance optical modul es on all ports, normal temperature, dual AC power m odules)
    450 W (100% traffic load, long-distance optical modul es on all ports, 40°C, dual AC power modules)
    629 W (100% traffic load, QSFP28 short-distance o ptical modules on 64 ports, normal temperature, du al AC power modules)
    965 W (100% traffic load, QSFP28 long-distance op tical modules on 64 ports, 40°C, dual AC power mo dules)
    Power factor
    0.85 @ 15%-25% load
    0.92 @ 25%-50% load
    0.98 @ 50%-100% load
    0.90 @ 15%-25% load
    0.96 @ 25%-100% load
    0.98 @ 100% load
    2.Performance and Scalability
    Item
    CloudEngine 8850E - 32CQ-EI
    CloudEngine 8850-64CQ- EI
    Maximum number of MAC address entries
    288K
    264K
    Maximum number of routes (FIB IPv4)
    380K
    360K
    IPv4 FIB entry specification (Flexible resource mode)
    1. Flexible resource mode
    excluding route resources: same as the specifications in large MAC table mode
    2. Flexible resource mode including route resources: 190,000
    1. Flexible resource mode excluding route resources: same as the specifications in large MAC table mode
    2. Flexible resource mode including route resources:
    (1) If the IPv6 route resource mode is not set to maximum IPv6 mode or maximum dual- stack mode: 180,000
    (2) If the IPv6 route resource mode is set to maximum IPv6 mode or maximum dual-stack mode:
    The IPv6 route resource mode is set to maximum IPv6 mode: 0 (not supporting IPv4 FIB)
    ARP size
    Large ARP table mode:
    168,000 per chassis; Standard mode (default mode): 64,000 per chassis; Flexible resource mode including ARP resources: 104,000 per chassis;
    Large ARP mode: 156,000; standard mode (default mode):
    48,000 (among which 8,000 entries;Flexible resource mode including ARP resources: 92,000;
    Maximum number of VRFs
    4096
    2048
    IPv6 ND table size
    Large ARP table mode: 64,000 per chassis;Large MAC table/Large ACL/flexible resource mode excluding ARP or route resources: 8,000 per chassis;
    Standard mode (default mode):
    1. If the IPv6 route resource mode is not set to shared mode, the specification is 8,000 ND entries per chassis.
    2. If the IPv6 route resource mode is set to shared mode, the specification is 64,000 ND entries per chassis.
    Large ARP table mode: 48,000;Standard mode (default mode):
    1. If the IPv6 route resource mode is not set to maximum IPv6 mode or maximum dual- stack mode: 4,000;
    2. If the IPv6 route resource mode is set to maximum IPv6 mode or maximum dual-stack mode: 48,000;
    Flexible resource mode:
    1. Flexible resource mode excluding ARP or route resources: same as the specifications in large MAC table mode;
    2. Flexible resource mode including ARP resources: same as the specifications in large ARP table mode;
    3. Flexible resource mode including route resources: same as the standard mode;
    Maximum number of VRRP groups
    1000 (shared by VRRP and VRRP6)
    1000 (shared by VRRP and VRRP6)
    Maximum number of ECMP paths
    128
    128
    Maximum number of VXLAN bridge domains
    M-LAG:4,000
    Others:16,000
    8000
    Maximum number of BDIF interfaces
    Default mode: 4,000
    Large overlay mode: 8,000
    4000
    Maximum number of LAGs
    1024
    1024
    Maximum number of links in a LAG
    Maximum number of LAGs x Maximum number of members in a LAG:
    1024*2
    512*4
    256*8
    128*16
    64*32
    Maximum number of LAGs x Maximum number of members in a LAG:
    1024*2
    512*4
    256*8
    128*16
    64*32
    32*64
    Maximum number of VLANs where VBST can be configured
    The number of instances supported by VBST is 500, the static instance configuration range is 1 to 63, and the dynamic instance is specified from 1 to 500.
    The number of instances supported by VBST is 500, the static instance configuration range is 1 to 63, and the dynamic instance is specified from 1 to 500.
    3.Ordering Information
    Active Device
    CE8850-EI-F-B0B
    CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,Port-side Exhaust)
    CE8850-EI-B-B0B
    CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,Port-side Intake)
    CE8850-64CQ-EI
    CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,Without Fan and Power Module)
    CE8850E-32CQ-EI
    CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,without fan and power module)
    CE8850E-32CQ-EI-B
    CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,2*AC power module,4*fan module,port- side intake)
    CE8850E-32CQ-EI-F
    CE8850E-32CQ-EI Switch(32*100GE QSFP28, 1*10GE SFP+, 2*AC power module,4*fan module, port-side exhaust)
    Power module
    Model
    Description
    Applicable product
    PHD-1K2WA-F
    1200W HVDC Power Module(Power panel side intake)
    CE8850-64CQ-EI
    PHD-1K2WA-B
    1200W HVDC Power Module(Power panel side exhaust)
    CE8850-64CQ-EI
    PDC-1K2WA-B
    1200W DC Power Module(Power panel side intake)
    CE8850-64CQ-EI
    PDC-1K2WA-F
    1200W DC Power Module(Power panel side exhaust)
    CE8850-64CQ-EI
    PAC1K2S12-PB
    1200W AC&240V DC Power Module (Back to Front,Power panel side exhaust)
    CE8850-64CQ-EI
    PAC1K2S12-PF
    1200W AC&240V DC Power Module (Front to Back,Power panel side intake)
    CE8850-64CQ-EI
    PHD1K2S12-DB
    1200W HVDC Power Module (Back to Front,Power panel side exhaust)
    CE8850E-32CQ-EI
    PDC1000S12-DB
    1000W DC Power Module (Power panel side exhaust)
    CE8850E-32CQ-EI
    PDC1000S12-DF
    1000W DC Power Module (Power panel side intake)
    CE8850E-32CQ-EI
    PAC600S12-EB
    600W AC&240V DC Power Module (Back to Front,Power panel side exhaust)
    CE8850E-32CQ-EI
    PAC600S12-EF
    600W AC&240V DC Power Module (Front to Back,Power panel side intake)
    CE8850E-32CQ-EI
    Fan module
    Model
    Description
    Applicable product
    FAN-180A-F
    Fan box(F,FAN panel side intake)
    CE8850-64CQ-EI
    FAN-180A-B
    Fan box(B,FAN panel side exhaust)
    CE8850-64CQ-EI
    FAN-031A-F
    Fan box(F,FAN panel side intake)
    CE8850E-32CQ-EI
    FAN-031A-B
    Fan box(B,FAN panel side exhaust)
    CE8850E-32CQ-EI
    Software
    CE88-LIC-BUN01
    CE8800 Function License Bundle 1
    CE88-LIC-TLM
    CE8800 Telemetry Function
    CE88-LIC-PTP
    CE8800 PTP Function (supported only by the CE8850-64CQ-EI)
    CE88-LIC-AIF
    CloudEngine 8800 AI Fabric Function
    N1-CE88LIC-CFFD
    N1-CloudFabric Foundation SW License for CloudEngine 8800
    N1-CE88CFFD-SnS1Y
    N1-CE8800 CloudFabric Foundation Software Package-Subscription and Support-Year
    N1-CE88LIC-CFAD
    N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year
    N1-CE88CFAD-SnS1Y
    N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year
    N1-CE88LIC-CFPM
    N1- CloudEngine 8800 CloudFabric Premium Software Package
    N1-CE88CFPM-SnS1Y
    N1- CloudEngine 8800 CloudFabric Premium Software Package-Subscription and Support-Year
    N1-CE88LIC-AIF
    N1-CloudEngine 8800 AI Fabric Function
    N1-CE88AIF-SnS1Y
    N1-CE8800 AI Fabric Function-Subscription and Support-Year
    N1-CE88LIC-HPC
    N1-CloudEngine 8800 AI Fabric HPC Scenario Value-added Package
    N1-CE88HPC-SnS1Y
    N1-CloudEngine 8800 AI Fabric HPC Storage Scenario Value-added Package-Subscription and Support-Year
    N1-CE-F-LIC-MDCA
    N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed
    N1-CEFMDCA -SnS1Y
    N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed Device- Subscription and Support-Year
    N1-CE88UPG-F-A
    N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced
    N1-CE88UGFA-SnS1Y
    N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced- Subscription and Support-Year
    N1-CE88UPG-A-P
    N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium
    N1-CE88UGAP-SnS1Y
    N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium-Subscription and Support-Year
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    COMPANY PROFILE
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Why Choose Us
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Exhibition
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Certifications
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Client Evaluation
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Packing & Delivery
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    1. Who are we?
    We are based in Beijing, China, start from 2023,sell to Domestic Market(60.00%),North America(20.00%),South America(10.00%),Western Europe(10.00%). There are total about 11-50 people in our office.

    2. How can we guarantee quality?
    Always a pre-production sample before mass production;
    Always final Inspection before shipment;

    3. What can you buy from us?
    Microwave Equipment, Data Communication Equipment, Transmission Equipment, Storage Device, Server

    4. Why should you buy from us not from other suppliers?
    Microwave equipment:RTN910A/RTN905F/RTN950/RTN950A/RTN980/RTN980L/RTN320F/RTN380AX; Wavelength division equipment:OSN9800/OSN9600/ONS8800; OLT:MA5800X2/X7; Switch:S9310X/CE6881-48S6CQ-B/CE8851-32CQ8DQ-P/CE6863E-48S6CQ. OceanStor Dorado 6000 V6/2288H V6/5288V6

    5. What services can we provide?
    Accepted Delivery Terms: FOB,EXW;
    Accepted Payment Currency:USD,CNY;
    Accepted Payment Type: T/T;
    Language Spoken:English,Chinese
    Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG
    Quality Hua Wei Cloudengine 8800 Series CE8850-64CQ-EI Data Center Network Switch with M-LAG for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Shandian Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)